Knowledge Base
Data center infrastructure knowledge base
Guides, questions and terms on precision cooling, environmental monitoring, gas suppression and maintenance, reviewed by Berdata experts.
- 7 guides
- 20 questions
- 20 terms
Knowledge Base
Guides
- How does an FM-200 gas suppression system work? Components and design stepsFM-200 (HFC-227ea) systems discharge a clean extinguishing agent into the protected volume within about 10 seconds of fire detection; the agent extinguishes mainly by absorbing heat from the flame and leaves no residue. A system consists of detection, a control panel, agent cylinders, piping and nozzles, and is designed around the integrity of the protected volume.
- Free cooling and adiabatic cooling: saving energy in the data centerFree cooling uses cool outdoor conditions instead of compressors whenever the outside is cool enough; adiabatic cooling pre-cools air by evaporating water and extends the hours in which free cooling is possible. Together they can substantially reduce mechanical cooling and energy consumption.
- In-row, perimeter and in-rack cooling: which one when?Perimeter units cool the whole room from its edges and are efficient in large, medium-density spaces. In-row units sit between racks and capture heat at the source, which suits high-density racks. In-rack coolers are a compact solution for a single rack or very small rooms.
- What is a hot and cold aisle layout and how is it set up?A hot and cold aisle layout arranges racks front-to-front (cold aisle) and back-to-back (hot aisle) so that cold supply air and hot exhaust air do not mix. When one of the aisles is contained, precision cooling units deliver a more stable temperature with less energy.
- Server room preventive maintenance plan: what, and how often?Preventive maintenance is the planned inspection of precision cooling, environmental monitoring and gas suppression systems before they fail. Filters, drains, refrigerant pressures, fans, electrical connections and sensors are checked at set intervals and findings are recorded. A good plan clearly reduces sudden failures and the need for emergency response.
- Server room environmental monitoring guide: which sensor goes where?Effective environmental monitoring brings temperature readings from rack fronts, room humidity, water leaks, smoke, door status and power into one system, and routes alarms to the right people. Sensor placement matters more than sensor count: a sensor in the wrong spot reports problems too late.
- Server room cooling guide: choosing precision cooling and sizing the capacityThe cooling requirement of a server room starts with the electrical power drawn by its IT equipment, almost all of which turns into heat. The heat load is calculated first, redundancy and growth margins are added, and only then are the system type (DX or chilled water) and the air distribution method chosen.
Knowledge Base
Frequently asked questions
- How does 24/7 emergency response work?Maintenance and service
- Do you maintain precision cooling units of other brands?Maintenance and service
- Does FM-200 damage equipment or data?Gas fire suppression
- How is the FM-200 quantity calculated?Gas fire suppression
- Is FM-200 dangerous for people?Gas fire suppression
- What is FM-200 and how does it extinguish fire?Gas fire suppression
- How often should precision cooling be maintained?Maintenance and service
- What is the difference between precision and comfort air conditioning?Cooling and air conditioning