Data center design and infrastructure optimization
A well-designed data center runs more safely on less energy. Berdata takes on design for new facilities and infrastructure optimization for existing ones, treating cooling, layout and power together.
Data center design and infrastructure optimization
Scope
- 01Raised floor
- 02Cabinet layout
- 03Hot / cold aisle containment
- 04IT cooling
- 05Uninterruptible power planning
Data center design and infrastructure optimization
How we work
- 01Current-state analysis and site survey
- 02Design and engineering
- 03Implementation
- 04Commissioning and maintenance
Data center design and infrastructure optimization
From the knowledge base
- Free cooling and adiabatic cooling: saving energy in the data centerFree cooling uses cool outdoor conditions instead of compressors whenever the outside is cool enough; adiabatic cooling pre-cools air by evaporating water and extends the hours in which free cooling is possible. Together they can substantially reduce mechanical cooling and energy consumption.
- How is precision cooling capacity calculated?Capacity is based on the total heat load of the room: the power drawn by IT equipment (almost all of which becomes heat), UPS losses, lighting and building loads are added up. A moderate growth margin is added, a separate unit is planned for redundancy (N+1), and selection is based on sensible (dry) capacity rather than total capacity.
- In-row, perimeter and in-rack cooling: which one when?Perimeter units cool the whole room from its edges and are efficient in large, medium-density spaces. In-row units sit between racks and capture heat at the source, which suits high-density racks. In-rack coolers are a compact solution for a single rack or very small rooms.
- Aisle containmentAisle containment physically encloses the hot or cold aisle with roof panels and end-of-row doors to stop cold supply air mixing with hot exhaust air. It raises cooling efficiency and gives more stable rack inlet temperatures.
- N+1 redundancyN+1 redundancy means adding one spare to the number of units required to carry the load (N), so the system keeps running when one unit fails or is under maintenance. It is a basic design principle for precision cooling, UPS and other critical infrastructure.
- What is N+1 redundancy and does a server room need it?N+1 means adding one standby unit to the number of units required to carry the load (N), so that cooling continues when a unit fails or is under maintenance. It is recommended for any server room that is critical to business continuity; a room with a single unit is at risk at that unit’s first failure.