Solutions
FM-200 gas fire detection and suppression
Unlike water or powder, FM-200 gas suppression tackles fire without damaging electronic equipment. Berdata handles the system end to end, from calculating the protected volume to engineering, installation and periodic inspection.
- DSmoke / heat detector
FM-200 gas fire detection and suppression
Scope
- 01Fire detection
- 02Gas suppression that leaves electronics unharmed
- 03Protected volume calculation
- 04Engineering design
- 05Installation
- 06Periodic inspection
FM-200 gas fire detection and suppression
3D view
3D view is not supported on this device.
FM-200 gas fire detection and suppression
How we work
- 01Site survey and volume calculation
- 02Engineering design
- 03Installation and commissioning
- 04Periodic inspection
FM-200 gas fire detection and suppression
From the knowledge base
- FM-200 (HFC-227ea)FM-200 is the trade name of heptafluoropropane (HFC-227ea). This colourless, odourless and non-conductive clean agent extinguishes fire mainly by absorbing heat from the flame and leaves no residue.
- Does FM-200 damage equipment or data?No. FM-200 is electrically non-conductive and leaves no residue; equipment does not get wet and needs no cleaning. That is why it is preferred in rooms with energized electronic equipment. Fast extinguishing also limits the damage the fire itself can cause.
- How is the FM-200 quantity calculated?The quantity is calculated from the net protected volume, the lowest design ambient temperature and the design concentration defined in the standard (TS EN 15004 or NFPA 2001) for the fire class. Raised-floor voids and ceiling voids are treated as separate volumes, and the result is verified with a hydraulic calculation of pipes and nozzles.
- How does an FM-200 gas suppression system work? Components and design stepsFM-200 (HFC-227ea) systems discharge a clean extinguishing agent into the protected volume within about 10 seconds of fire detection; the agent extinguishes mainly by absorbing heat from the flame and leaves no residue. A system consists of detection, a control panel, agent cylinders, piping and nozzles, and is designed around the integrity of the protected volume.
- Is FM-200 dangerous for people?In a system designed to the standards, FM-200 is discharged at concentrations approved for occupied spaces; the design concentration is kept below the no-observed-adverse-effect level (NOAEL, 9%). Even so, the room must be evacuated during discharge; the fire itself and its combustion products are the real hazard.
- What is FM-200 and how does it extinguish fire?FM-200 is a clean extinguishing agent, chemically heptafluoropropane (HFC-227ea), that is colourless, odourless and electrically non-conductive. It extinguishes fire mainly by absorbing heat from the flame and leaves no residue, which is why it is used where electronic equipment is installed, such as server rooms, data centers and electrical rooms.
Quick site survey request
Tell us what you need. Our expert will call you.
- 01Send your request
- 02Expert response
Expert response within 24 hours - 03Site survey and quote
An on-site survey is carried out if needed and a tailored quote is prepared.