Solutions

Cooling and air conditioning

Berdata Bilişim provides high-efficiency precision cooling and air conditioning for data centers and critical infrastructure. Guided by energy efficiency, sustainability and operational continuity, it delivers end-to-end solutions with systems designed for each project. In this field it serves as the exclusive distributor for Türkiye and Northern Cyprus of HiRef S.p.A., part of Galletti Group.

Hot / cold aisle, isometric viewThe precision cooling unit pushes cold air under the raised floor; it rises through perforated tiles into the contained cold aisle, enters the cabinets at the front, leaves hot at the back and returns to the unit at ceiling level.Precision coolingCold aisle containmentHot air returnCabinet rowPerforated tilesRaised floor
Principle diagram · not to scaleCold airHot air

Cooling and air conditioning

Scope

  1. 01Precision air conditioning systems for data centers
  2. 02Telecom and cabinet cooling solutions
  3. 03Container and modular data center cooling systems
  4. 04Free-cooling and adiabatic cooling technologies
  5. 05Chiller systems (Databatic and free cooling)
  6. 06Industrial process cooling and heat pump solutions
  7. 07Hydronic kits and high-performance air systems
  8. 08Advanced control and monitoring infrastructure

Which product for which environment?

Which HiRef series for which environment?

Which HiRef series for which environment?
Environment / needRecommended seriesCapacity
Single rack or in-rack high densityMRAC CW / DXRack-mounted mini cooler; chilled water or DX.3–9 kW
Small and medium server roomHTI CW · JREFChilled-water HTI CW for medium and small server rooms, or compact perimeter JREF.6–45 kW
High-density rack rowsNRCD / NRCV · HRCCIn-row DX or chilled-water units, with hot / cold aisle containment.12–57 kW
Data center white spaceTRF · NRG · TREF DXChilled-water or DX perimeter units; free-cooling and dual-cooling versions.9–374 kW
Large-scale data center with energy efficiency as priorityHDB · FanWallAdiabatic air-to-air systems and high-density fan-wall solutions.10–460 kW
Telecom, containers and panelsTelekom ve kabin tipi seriIndoor and outdoor DX units, optional free cooling.3–35 kW

Capacities are the ranges in the HiRef 2026 catalog and are for preliminary selection only. The final model is defined by Berdata experts after a heat load calculation and site survey.

Cooling and air conditioning

How we work

  1. 01Site survey and needs analysis (data centers, UPS, telecom, electrical and transformer rooms, laboratories, archives)
  2. 02Expert support, capacity sizing and product selection
  3. 03Installation and commissioning
  4. 04After-sales support, preventive maintenance and 24/7 response

Cooling and air conditioning

Documents

Quick site survey request

Tell us what you need. Our expert will call you.

  1. 01Send your request
  2. 02Expert response
    Expert response within 24 hours
  3. 03Site survey and quote
    An on-site survey is carried out if needed and a tailored quote is prepared.

+90 (212) 320 11 33info@berdata.com.tr