Environmental monitoring and central supervision
Most failures in a server room start as a small deviation. Environmental monitoring lets you see these deviations before they become alarms. With Vutlan and Room Alert, Berdata continuously monitors critical parameters and gathers UPS, generator and cooling alarms in a single center.
- TTemperature / humidity
- WWater leak
- SSmoke
- PPower / voltage
- AAirflow
Environmental monitoring and central supervision
Scope
- 01Temperature
- 02Humidity
- 03Water leak
- 04Power / voltage
- 05Smoke
- 06Airflow
- 07UPS, generator and cooling alarms in a single center
Which one for which environment?
Vutlan or Room Alert?
| Criterion | Vutlan | Room Alert |
|---|---|---|
| Best suited for | Data centers, telecom sites, industrial facilities, wide areas | Server rooms, telecom closets, remote locations |
| Key approach | Up to 150 sensors per unit; automation with logic schemes, LoRaWAN wireless sensors, managed PDUs | Plug-and-play, fast deployment with PoE |
| Integration / management | SNMP v1/v2c/v3, Modbus TCP / RTU, 4-20 mA, API | Cloud (Room Alert Account) or on premises (Room Alert Manager), SNMP |
| With Berdata | Exclusive distributor for Türkiye and Northern Cyprus since 2026 | Exclusive distributor for Türkiye and Northern Cyprus since 2013 |
| Vutlan quote | Room Alert quote |
Which product for which environment?
Ready-made Room Alert packages
| Environment / need | Recommended series | Capacity |
|---|---|---|
| Data center | Room Alert 32S + 7 sensörTemperature and humidity, active power with temperature, temperature and airflow, particulate and temperature, cable flood (8’), main power and room entry sensors. | 32+ sensör |
| Server room | Room Alert 12S + 6 sensörTemperature and humidity, temperature and airflow, particulate and temperature, cable flood (8’), main power and room entry sensors. | 12+ sensör |
| Indoor air quality (offices, production areas) | Room Alert 12SR + 3 sensörPM2.5 and PM10 particulate measurement; temperature and airflow plus temperature and humidity sensors. | 12+ sensör |
| Heat safety (warehouses, work areas) | Room Alert 3S + 1 sensörA 25’ temperature and humidity sensor that monitors temperature, humidity, heat index and dew point together. | dahili + 2 port |
Package contents follow the AVTECH 2025 catalog. After a site survey Berdata adapts the package to your environment by adding or removing sensors; the same need can also be met with Vutlan units.
Environmental monitoring and central supervision
From the knowledge base
- LoRaWANLoRaWAN is a wireless network protocol that transmits data over long distances with low power. In environmental monitoring it lets battery-powered sensors run for years without cabling, suiting large areas, scattered buildings and hard-to-cable locations.
- ModbusModbus is a widely used protocol for data exchange between industrial devices. It runs as Modbus RTU over serial lines and Modbus TCP over networks; monitoring systems use it to read data from UPS, generators, energy meters and cooling units.
- How does an environmental monitoring device send alarms?Monitoring devices can send alarms through several channels such as email, SMS, voice calls, mobile app notifications and SNMP traps; some models also support messaging services such as Telegram and local light/sound alarms. The recommended setup is at least two channels and an escalation chain that moves to the next person if there is no response.
- Where should temperature sensors be placed on a rack?Temperature sensors belong at the front of the rack, where servers draw in air, ideally at bottom, middle and top. Racks furthest from the cooling unit, at row ends and with the highest density take priority. A sensor at the rear measures exhaust air, which is informative but no substitute for inlet temperature.
- Server room environmental monitoring guide: which sensor goes where?Effective environmental monitoring brings temperature readings from rack fronts, room humidity, water leaks, smoke, door status and power into one system, and routes alarms to the right people. Sensor placement matters more than sensor count: a sensor in the wrong spot reports problems too late.
- Which parameters should be monitored in a server room?At a minimum: temperature (at rack fronts), humidity, water leaks, smoke, door status and power (mains, UPS, generator). Adding cooling unit alarms, airflow and rack currents means most failures are noticed before an outage occurs.
Environmental monitoring and central supervision
Documents
- CatalogueRoom Alert product catalogue 2023Download: Room Alert product catalogue 2023
- CatalogueRoom Alert product catalogue 2025Download: Room Alert product catalogue 2025
- CatalogueVutlan product catalogue (October 2025)Download: Vutlan product catalogue (October 2025)
- BrochureVutlan VT825GG flyerDownload: Vutlan VT825GG flyer