In critical infrastructure, failures are prevented before they happen. Berdata performs preventive maintenance, with authorized access and logged work, on precision cooling units from HiRef and other brands. Emergency response time is set according to your location and contract and guaranteed by contract.
Brand-independent preventive maintenance and 24/7 support
Scope
- 01Preventive maintenance with authorized access and logged work
- 02Brand-independent service
- 0324/7 support
- 04Emergency response under a contractual SLA
SLA
SLA response times
| Emergency response time | 2 hours | 4 hours | 6 hours | 12 hours | 24 hours | 48 hours |
|---|
The response time that applies to your location is set in your maintenance contract after the site survey.
Brand-independent
Brands we maintain
- HiRef
- Climaveneta
- Liebert & Hiross
- STULZ
- DENCO
- RC
Brand-independent preventive maintenance and 24/7 support
From the knowledge base
- How does 24/7 emergency response work?Customers with a maintenance contract can reach the emergency line around the clock; a fault ticket is opened and an expert is dispatched within the response time (SLA) defined in the contract. Berdata’s SLA levels are defined as 2, 4, 6, 12, 24 and 48 hours; the level is set in the contract.
- Do you maintain precision cooling units of other brands?Yes. In addition to HiRef, for which it is the distributor, Berdata provides preventive maintenance and repairs for precision cooling units of other brands such as Climaveneta, Liebert & Hiross, STULZ, DENCO and RC. Existing equipment is inspected during a site survey and a condition report is prepared before the contract.
- How does an FM-200 gas suppression system work? Components and design stepsFM-200 (HFC-227ea) systems discharge a clean extinguishing agent into the protected volume within about 10 seconds of fire detection; the agent extinguishes mainly by absorbing heat from the flame and leaves no residue. A system consists of detection, a control panel, agent cylinders, piping and nozzles, and is designed around the integrity of the protected volume.
- How often should precision cooling be maintained?Preventive maintenance for precision cooling is scheduled quarterly at most sites; filters may be checked more often depending on dust levels. Comprehensive work such as coil cleaning, calibration and testing the standby unit is done at least once a year. The exact interval depends on the manufacturer’s recommendation, the age of the equipment and room conditions.
- What is checked during preventive maintenance?For precision cooling: filters, drain pan and line, humidifier, fans and motors, electrical connections, refrigerant pressures and compressor currents are checked; alarm history is reviewed and operating values are recorded. Monitoring sensors and alarm notifications are tested, and in gas suppression systems cylinder pressure and detection are checked.
- What is N+1 redundancy and does a server room need it?N+1 means adding one standby unit to the number of units required to carry the load (N), so that cooling continues when a unit fails or is under maintenance. It is recommended for any server room that is critical to business continuity; a room with a single unit is at risk at that unit’s first failure.