Berdata Bilişim provides high-efficiency precision cooling and air conditioning for data centers and critical infrastructure. Guided by energy efficiency, sustainability and operational continuity, it delivers end-to-end solutions with systems designed for each project. In this field it serves as the exclusive distributor for Türkiye and Northern Cyprus of HiRef S.p.A., part of Galletti Group.
Cooling and air conditioning
Scope
- 01Precision air conditioning systems for data centers
- 02Telecom and cabinet cooling solutions
- 03Container and modular data center cooling systems
- 04Free-cooling and adiabatic cooling technologies
- 05Chiller systems (Databatic and free cooling)
- 06Industrial process cooling and heat pump solutions
- 07Hydronic kits and high-performance air systems
- 08Advanced control and monitoring infrastructure
Which product for which environment?
Which HiRef series for which environment?
| Environment / need | Recommended series | Capacity |
|---|---|---|
| Single rack or in-rack high density | MRAC CW / DXRack-mounted mini cooler; chilled water or DX. | 3–9 kW |
| Small and medium server room | HTI CW · JREFChilled-water HTI CW for medium and small server rooms, or compact perimeter JREF. | 6–45 kW |
| High-density rack rows | NRCD / NRCV · HRCCIn-row DX or chilled-water units, with hot / cold aisle containment. | 12–57 kW |
| Data center white space | TRF · NRG · TREF DXChilled-water or DX perimeter units; free-cooling and dual-cooling versions. | 9–374 kW |
| Large-scale data center with energy efficiency as priority | HDB · FanWallAdiabatic air-to-air systems and high-density fan-wall solutions. | 10–460 kW |
| Telecom, containers and panels | Telekom ve kabin tipi seriIndoor and outdoor DX units, optional free cooling. | 3–35 kW |
Capacities are the ranges in the HiRef 2026 catalog and are for preliminary selection only. The final model is defined by Berdata experts after a heat load calculation and site survey.
Cooling and air conditioning
How we work
- 01Site survey and needs analysis (data centers, UPS, telecom, electrical and transformer rooms, laboratories, archives)
- 02Expert support, capacity sizing and product selection
- 03Installation and commissioning
- 04After-sales support, preventive maintenance and 24/7 response
Exclusive distributor
Brands in this solution
Cooling and air conditioning
From the knowledge base
- Adiabatic coolingAdiabatic cooling lowers air temperature using the heat absorbed when water evaporates. In data centers it is mainly used to pre-cool outdoor air and so extend the hours in which free cooling is possible.
- ChillerA chiller is a central unit that cools water through a refrigeration cycle and supplies it to cooling units. Models with free-cooling coils or adiabatic cooling reduce compressor use when outdoor air is cool.
- CRACA CRAC (Computer Room Air Conditioner) is a DX-type computer room unit that cools with its own compressor. Refrigerant evaporates inside the unit and heat is rejected outdoors through a condenser.
- CRAHA CRAH (Computer Room Air Handler) is a computer room unit without a compressor that works with chilled water from a central chiller. Fans move room air across a chilled-water coil.
- DX (direct expansion)In DX (direct expansion) systems, refrigerant evaporates directly in the coil that cools the air, without a secondary fluid such as water. Each unit has its own compressor and an air- or water-cooled condenser.
- Free coolingFree cooling means cooling with cool outdoor air or conditions instead of compressors when the outside is cool enough. It can be partial or full and lowers energy consumption and PUE in data centers.
Cooling and air conditioning
Documents
- CatalogueHiRef product catalogue 2026Download: HiRef product catalogue 2026
Quick site survey request
Tell us what you need. Our expert will call you.
- 01Send your request
- 02Expert response
Expert response within 24 hours - 03Site survey and quote
An on-site survey is carried out if needed and a tailored quote is prepared.