Exclusive distributor for Türkiye and Northern Cyprus
Room Alert
Room Alert is an environmental monitoring system developed since 1988 by US-based AVTECH Software; according to the manufacturer, it has more than 250,000 references in 185 countries. It monitors temperature, humidity, power and environmental risks in real time and supports operational continuity and system security with early warnings. It runs with cloud (Room Alert Account) or on-premises (Room Alert Manager) management. Berdata has been Room Alert’s exclusive distributor for Türkiye and Northern Cyprus since 2013.


Room Alert
Highlights
- 01Plug-and-play, fast setup; single-cable operation with PoE
- 02Cloud (Room Alert Account) or on-premises (Room Alert Manager) management
- 03Email, SMS and mobile app alerts; integration with existing monitoring software over SNMP
- 04A model range that scales from telecom closets to data centers
- 05Backed by Berdata in Türkiye since 2013
Room Alert
Product images





Room Alert
3D view
3D view is not supported on this device.
Room Alert
Product families
- Room Alert 3SThe smallest model; built-in temperature sensor, 1 external digital sensor port and 1 switch sensor channel. For telecom closets, small rooms and remote locations; wired network and PoE.
- Room Alert 12S / 12SRFor mid-sized spaces; 3 digital sensor ports, 4 switch sensor channels, 1 analog port, 1 relay output. Wall-mount (12S) or rack-mount (12SR).
- Room Alert 32SThe flagship model, 19" 1U rack-mount. Built-in sensors monitor temperature, humidity, dew point, heat index and power out of the box; 8 digital sensor ports, 16 switch sensor channels, 2 analog inputs (0–5 V), 2 relay outputs and 2 light tower / relay adapter ports. PoE and a built-in UPS that keeps it running during power loss; capacity for 32+ sensors.
- Room Alert MAX (kablosuz)A wireless series for open offices, warehouses and shared spaces where cabling is difficult. The MAX base station (Ethernet / PoE and 2.4 GHz Wi-Fi, built-in temperature sensor), a wireless temperature and humidity sensor (−40…125 °C ±0.2 °C, 0–100% RH ±1.8%; 2+ years on AA batteries) and an adapter that turns existing wired Room Alert sensors wireless. About 30 m range to the base station; SNMP and BACnet support. Works in the same system as wired PRO devices.
- Yazılım ve mobil uygulamaThe Room Alert Account cloud dashboard with patented Monitor360 technology builds virtual sensors and alerts across multiple sensors, devices and locations. Room Alert Manager manages unlimited devices for organisations that need on-premises software; the free Room Alert app for iOS and Android shows and acknowledges alerts from anywhere.
- S serisi güvenlik özellikleriAll new-generation S models support SNMP v3, HTTPS, 2048-bit encryption and TLS email, for environments that need advanced security.
- SensörlerDigital temperature (−55…125 °C), temperature and humidity (−40…85 °C, 5–95% RH; shielded version for electrically noisy environments), outdoor and fluid temperature, extreme temperature (−200…500 °C), temperature and airflow, particulate (PM2.5 / PM10), active power (100–1800 W, no cable cutting), mains / UPS power, mini UPS and power sensor (15+ minutes of backup), current (0–50 A / 0–250 A), cable and spot flood, smoke, motion, door, relay switch and remote power control (iBoot). Cable lengths of 25’ / 50’ / 100’.
Room Alert
Technical summary
| Manufacturer | AVTECH Software Inc., USA (since 1988); devices are made in the USA |
|---|---|
| Warranty and support | 3-year warranty on monitors; lifetime support and free firmware updates (manufacturer data) |
| Reach (manufacturer data) | More than 250,000 references in 185 countries |
| Monitored parameters | Temperature, humidity, heat index, dew point, airflow, flooding, smoke, motion, door, power / current, power outage |
| Actions | Switching devices via relay outputs, light tower and relay adapter |
| Management | Room Alert Account (cloud), Room Alert Manager (on premises), SNMP |
| Notifications | Email, SMS, mobile app, SNMP trap |
| Typical use | Data centers, server / UPS / electrical rooms, telecom closets, vaccine rooms and pharmacy storage, laboratories, warehouses, ATMs |
| Distribution | Exclusive distributor for Türkiye and Northern Cyprus since 2013 |
Room Alert
From the knowledge base
- How does an environmental monitoring device send alarms?Monitoring devices can send alarms through several channels such as email, SMS, voice calls, mobile app notifications and SNMP traps; some models also support messaging services such as Telegram and local light/sound alarms. The recommended setup is at least two channels and an escalation chain that moves to the next person if there is no response.
- Where should temperature sensors be placed on a rack?Temperature sensors belong at the front of the rack, where servers draw in air, ideally at bottom, middle and top. Racks furthest from the cooling unit, at row ends and with the highest density take priority. A sensor at the rear measures exhaust air, which is informative but no substitute for inlet temperature.
- Server room environmental monitoring guide: which sensor goes where?Effective environmental monitoring brings temperature readings from rack fronts, room humidity, water leaks, smoke, door status and power into one system, and routes alarms to the right people. Sensor placement matters more than sensor count: a sensor in the wrong spot reports problems too late.
- Which parameters should be monitored in a server room?At a minimum: temperature (at rack fronts), humidity, water leaks, smoke, door status and power (mains, UPS, generator). Adding cooling unit alarms, airflow and rack currents means most failures are noticed before an outage occurs.
- SNMPSNMP (Simple Network Management Protocol) is the standard protocol for monitoring and managing networked devices. Monitoring units share sensor values over SNMP and send SNMP traps to existing network monitoring software when alarms occur.
- Where should water leak sensors be placed?Leak sensors go where water collects first: under precision cooling units and along drain lines, along pipe routes under raised floors, at the base of external walls and windows, and below services crossing the ceiling. Cable-type sensors are used for long runs and spot sensors for single points.
Room Alert
Documents
- CatalogueRoom Alert product catalogue 2023Download: Room Alert product catalogue 2023
- CatalogueRoom Alert product catalogue 2025Download: Room Alert product catalogue 2025
Quick site survey request
Tell us what you need. Our expert will call you.
- 01Send your request
- 02Expert response
Expert response within 24 hours - 03Site survey and quote
An on-site survey is carried out if needed and a tailored quote is prepared.