Vutlan
Vutlan is a Bratislava-based EU technology company that manufactures smart IoT devices and sensors for monitoring and controlling critical IT infrastructure, with all products made in Europe. From server rooms to data centers, telecom sites and industrial facilities, it brings temperature, humidity, water leak, power and door status into a single web interface and connects to existing systems over SNMP, Modbus and API. Since January 2026 Berdata has been Vutlan’s exclusive distributor for Türkiye and Northern Cyprus.
New

Vutlan
Highlights
- 01Monitoring units that scale from small server rooms to data centers (up to 150 sensors per unit)
- 02Wired (CAN daisy-chain) and LoRaWAN wireless sensors side by side
- 03Automatic actions with code-free logic schemes, timers and triggers
- 04Alarm notifications by email, SMS, voice call, SNMP trap and Telegram
- 05Integration over SNMP v1/v2c/v3, Modbus TCP/RTU, 4-20 mA and API (XML / JSON)
- 06Engineering, installation and support by Berdata experts
Vutlan
Product images






Vutlan
3D view
3D view is not supported on this device.
Vutlan
Product families
- İzleme üniteleri (VT225t, VT335t, VT336t)Compact units for small offices, server rooms and racks; up to 100 physical sensors and 700 elements. The VT335t adds redundant 12 V DC power and an LTE modem slot; the VT336t adds a 24–48 V DC input for industrial use.
- Veri merkezi izleme üniteleri (VT825GG, VT825t, VT855t)19" 1U with redundant power and network; up to 130–150 sensors and 1000 elements. Modbus RTU extension slot, backup battery option and 24–48 V DC versions.
- LoRaWAN kablosuz çözümler (LR800, LR490, LR530, LR590)LR800 gateway (8 channels, up to 800 elements, optional 4G) and wireless sensors with a 10-year battery life. LR490 temperature and humidity, LR530 door and temperature, LR590 water leak with temperature and humidity. For wide areas and sites where cabling is not practical.
- Yönetilebilir PDU’lar (VT604t, VT608t, VT-PDU 4PS)Rack power distribution units with per-outlet switching, remotely or by logic rule; metered versions measure voltage, current, power and energy.
- SensörlerTemperature (indoor and outdoor), humidity, pressure, water leak (spot and cable), smoke, dust, vibration, airflow, PIR and radar motion, door, AC / DC voltage and current, 4-20 mA converter; USB camera. Up to 32 sensors per CAN chain.
- Genişleme ve iletişim modülleriAnalog sensor and dry-contact extension units, Modbus RTU module, LTE / 4G modem, relay and dry-contact outputs, light and sound alarms, backup batteries.
Featured model
VT825GG data center monitoring unit
A 19" 1U monitoring unit for data centers and large server rooms. A single unit monitors 130 sensors and 1000 elements; redundant power inputs and gigabit Ethernet keep it running without interruption. Sensors, dry contact inputs, relays and Modbus / SNMP integration come together in one interface.


| Capacity | 130 sensors, 1000 elements |
|---|---|
| Ethernet | 10/100/1000 Mbps |
| Redundant power | 2 × 100–240 V AC 50/60 Hz inputs, 1 × 12 V DC; 24–48 V DC order option |
| Analog ports | 8 sensor ports (expandable) |
| CAN port | 1 port; up to 32 sensors and extension units |
| Dry contact inputs | 16 inputs |
| Relays | 2 outputs (12 V DC, 0.25 A); 2 bistable power relays (NC/NO/COM) |
| Logging | microSD (up to 500 GB SDXC), USB flash, email, FTP |
| USB | USB camera, USB flash, USB hub |
| LTE modem slot | Ethernet and SMS backup (VT740 modem ordered separately) |
| Extension | VT485m Modbus RTU extension slot |
| Protocols | SNMP v1/v2c/v3, Modbus TCP/IP, 4–20 mA, 0–10 V, CAN; HTTP/HTTPS, SMTP, RADIUS, Syslog, NTP |
| Security | OpenVPN, SSL, HTTPS; three-tier user permissions |
| Notifications | Email, SMS, phone call, SNMP traps |
| Automation | Virtual sensors, timers, triggers, logic schemes, PING, IP cameras |
| API | XML, JSON |
| Interface | Responsive web interface, multi-language mobile interface, first-time wizard, sensor graphs |
| CPU / memory | 2 cores 720 MHz, 128 MB RAM, Linux |
| Mounting | 19" 1U (brackets included) |
| Warranty | 3 years |
Vutlan
Technical summary
| Manufacturer | Vutlan s.r.o., Bratislava, Slovakia (EU); products made in the EU |
|---|---|
| Monitored parameters | Temperature, humidity, pressure, water leak, smoke, dust, vibration, airflow, motion, door, voltage, current, energy |
| Protocols | SNMP v1/v2c/v3, Modbus TCP / RTU, 4-20 mA, 0-10 V, CAN, LoRaWAN, HTTP(S), API (XML / JSON), Syslog |
| Notifications | Email, SMS, voice call, SNMP trap, Telegram, light / sound alarm |
| Capacity | 100–150 sensors and 700–1000 elements per unit |
| Warranty | 3 years (monitoring units) |
| Typical use | Data centers, server rooms, racks, telecom sites, industrial facilities, offices |
| Distribution | Exclusive distributor for Türkiye and Northern Cyprus since January 2026 |
Vutlan
From the knowledge base
- LoRaWANLoRaWAN is a wireless network protocol that transmits data over long distances with low power. In environmental monitoring it lets battery-powered sensors run for years without cabling, suiting large areas, scattered buildings and hard-to-cable locations.
- ModbusModbus is a widely used protocol for data exchange between industrial devices. It runs as Modbus RTU over serial lines and Modbus TCP over networks; monitoring systems use it to read data from UPS, generators, energy meters and cooling units.
- How does an environmental monitoring device send alarms?Monitoring devices can send alarms through several channels such as email, SMS, voice calls, mobile app notifications and SNMP traps; some models also support messaging services such as Telegram and local light/sound alarms. The recommended setup is at least two channels and an escalation chain that moves to the next person if there is no response.
- Where should temperature sensors be placed on a rack?Temperature sensors belong at the front of the rack, where servers draw in air, ideally at bottom, middle and top. Racks furthest from the cooling unit, at row ends and with the highest density take priority. A sensor at the rear measures exhaust air, which is informative but no substitute for inlet temperature.
- Server room environmental monitoring guide: which sensor goes where?Effective environmental monitoring brings temperature readings from rack fronts, room humidity, water leaks, smoke, door status and power into one system, and routes alarms to the right people. Sensor placement matters more than sensor count: a sensor in the wrong spot reports problems too late.
- Which parameters should be monitored in a server room?At a minimum: temperature (at rack fronts), humidity, water leaks, smoke, door status and power (mains, UPS, generator). Adding cooling unit alarms, airflow and rack currents means most failures are noticed before an outage occurs.
Vutlan
Documents
- CatalogueVutlan product catalogue (October 2025)Download: Vutlan product catalogue (October 2025)
- BrochureVutlan VT825GG flyerDownload: Vutlan VT825GG flyer
Quick site survey request
Tell us what you need. Our expert will call you.
- 01Send your request
- 02Expert response
Expert response within 24 hours - 03Site survey and quote
An on-site survey is carried out if needed and a tailored quote is prepared.